alexa Vertically Aligned Pd Nanowires for Glucose Oxidase Bioanode | OMICS International
ISSN: 2155-6210
Journal of Biosensors & Bioelectronics

Like us on:

Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Vertically Aligned Pd Nanowires for Glucose Oxidase Bioanode

Gymama Slaughter* and Kweku Amoah

Department of Computer Science and Electrical Engineering, University of Maryland Baltimore County and Bioelectronics Laboratory, USA

*Corresponding Author:
Gymama Slaughter
Department of Computer Science and Electrical Engineering
of Maryland Baltimore County and Bioelectronics Laboratory
1000 Hilltop Circle, Baltimore, MD 21250, USA
Tel: +14104558483
Fax: +1410455396
E-mail: [email protected]

Received Date: August 10, 2012; Accepted Date: September 04, 2012; Published Date: September 05, 2012

Citation: Slaughter G, Amoah K (2012) Vertically Aligned Pd Nanowires for Glucose Oxidase Bioanode. J Biosens Bioelectron 3:124. doi: 10.4172/2155-6210.1000124

Copyright: © 2012 Slaughter G, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Biosensors & Bioelectronics

Abstract

A bioanode for glucose based biofuel cell have been fabricated by combining glucose oxidase and highly ordered Palladium (Pd) nanowire array electrode. The Pd nanowires were 5.57 μm in length and 64.28 nm in diameter. The hydrogel composite modified Pd nanowire array bioanodes were characterized with cyclic voltammetry in the presence of different scan rates and different substrate concentrations under physiological conditions. The electrochemical measurements showed a linear amperometric response in the range of 1 mM to 13 mM. In addition, surface and structural characterization were performed by scanning electron microscopy leading to the conclusion that the Pd nanowires are highly ordered and vertically aligned and thereby promotes the number of electroactive sites for the catalysis of the oxidation of glucose. The combination of glucose oxidase and Pd nanowire arrays revealed the capability of these enzymatic bioanodes to perform direct electron transfer to Pd nanostructure surfaces and be used in a glucose biofuel cell.

Keywords

Glucose oxidase; Pd nanowires; Bioanode; Cyclic voltammetry

Introduction

Enzymatic biofuel cells, especially glucose-O2 biofuel cells are fabricated from a variety of electrode materials [1]. Currently, there is a strong focus on the development of these biofuel cells for use as implantable and micro/ nano device power sources [2-9]. The desire to develop energy sources based on glucose biofuel cells for implantable devices can be attributed to the fact that the bioanode enzymes such as glucose oxidase and glucose dehydrogenase can oxidize glucose at physiological conditions. This permits the extracted glucose from the bloodstream or the interstitial fluid to be used as fuel substrate for energy harvesting under a physiologic conditions.

Typically, glucose-based biofuel cells consist of a bioanode and a biocathode at which oxidation-reduction (redox) reactions occur in the presence of the fuel source. The biofuel cell circuit is completed with an external load to allow the conduction of electrons from the bioanode to the biocathode (Figure 1). Therefore, the choice of the anodic and cathodic material depends on several factors including but not limited to the biocatalyst to catalyze the electrode reactions; the integration of the biocatalyst with the appropriate physicochemical transduction element for harvesting energy from the various concentration of glucose in blood or interstitial fluid; effective transduction element surface area in order to increase the number of binding sites for the biocatalyst; ease of fabrication; and enhanced durability to ensure extended functional lifetimes of biofuel cell devices for implantation [9-14]. Furthermore, a biocompatible encapsulating layer for the biofuel cell is required in order to enhance the biocompatibility and durability of the entire device in vivo.

biosensors-bioelectronics-biofuel-cell-oxidized

Figure 1: Schematic representation of the biofuel cell structure. Glucose is oxidized at the anode to gluconolactone and the electrons generated are transferred glucose oxidase to the Pd nanowires. The electrons are then transferred from the Pd nanowires to laccase at the cathode where oxygen is reduced to form water.

In this work, we describe the fabrication of a glucose biofuel cell bioanode based on the combination of glucose oxidase and Palladium (Pd) nanowire array electrodes, which has not been reported with respect to glucose-based biofuel cell applications. Pd nanowire array electrodes are high surface area three-dimensional bioanode, which are fabricated from Anodized Aluminum Oxide (AAO) template electrodeposition method [15-17]. These fabricated AAO templates are inherently ordered in nature and exhibits a highly self-arranged hexagonal array that permit them to be used as a template for the electrodeposition of metal species [18]. The nanowires formed on the electrode surface were characterized by Scanning Electron Microscopy (SEM). Glucose oxidase was covalent immobilized using a hydrogel composite membrane onto the Pd nanowire arrays. Cyclic voltammetry measurements were performed at different scan rates and in different glucose concentration to evaluate the electrocatalytic activity of the hydrogel composite modified Pd nanowire arrays [2,19]. In principle, the combination of glucose oxidase and Pd nanowire arrays leads to the development of a glucose oxidase bioanode that can oxide glucose, enhance the bioanode conductivity and facilitate the direct electron transfer of the biocatalyst without the use of a mediator [8].

Experimental

Materials and methods

AAO templates (10 mm×10 mm) with average pore diameter of 80 nm, pore density 2× 109 cm-2 and estimated porosity 15%, were purchased from Synkera Technologies, Inc. Glucose oxidase (GOx, EC 1.1.3.4 from Aspergillus niger), d-(+)-glucose, Hydroxyethylmethacrylate (HEMA), Tetraethyleneglycol Diacrylate (TEGDA), 2,2-Dimethoxy-2- Phenylacetophenone (DMPA, 99%), (3-aminopropyl)trimethoxysilane (γ-APS, 97%) and Poly(Ethylene Glycol) Methacrylate (PEGMA) were purchased from Sigma–Aldrich. The diacyrlate and methacrylate reagents were passed through an inhibitor removal column in order to remove the hydroquinone and monomethyl ether hydroquinone polymerization inhibitors before use. Glucose solutions were prepared using 0.1 M phosphate buffer saline (PBS, pH 7.3). Acryloyl(polyethyleneglycol)-N-hydroxysuccinamide (MW 3500), was purchased from Jenkem Technology. All supplementary chemicals were of analytical grades and solutions were prepared with 18.2 MΩ cm Milli-Q water.

Electrodeposition of Pd nanowires

The AAO templates were 98 ± 1μm in depth with a pore diameter of 80 ± 8 nm. Pd was electrochemically deposited from an aqueous solution containing 1 g L-1 Pd(NH3)4Cl2 (99.99%) and 10 g L-1 NH4Cl (99.99%). Ammonium hydroxide was used to adjust the pH to 8. Prior to electrodeposition, the AAO template was pretreated in acetone to clean the surface of the substrate followed by drying under nitrogen flow. A thin layer of Au (400 Å) was sputtered onto one side of the AAO template to provide an electrical conduction path for the electrodeposition of the Pd nanowires by exposing the pores of the AAO template to the underlying Au film. This provides a means for the electrodeposition of metal species through the pores. To create an electrical connection to the AAO working electrode, a polyethylene terephthalate film (0.8 cm×10 cm) was prepared with a thin film of Au (400 Å) and was attached to the Au sputtered side of the AAO substrate to allow for easy handling of the substrate material. A polyimide tape was used for electrode passivation and to define the electroactive area of the working electrode.

The prepared AAO substrate served as the working electrode in a three-electrode setup with a platinum mesh and a Ag/AgCl(sat) electrode as the counter and reference electrodes, respectively in an electrochemical cell with water jacket. The electrodeposition was performed at an applied potential of -600 mV with a BASi Epsilon Electrochemical Workstation and under a constant temperature of 30°C (Fischer Scientific Isotemp 3016D) with constant stirring for 8 hours. The mechanism of Pd nanowire deposition is described in the work of Tasaltin et al. [20] and should be Cheng et al. [21] and Peppas et al. [22]. After electrodeposition, the substrate was rinsed in deionized water and the AAO template was etched away in 2 M NaOH for 30 minutes at room temperature with agitation resulting in free standing Pd nanowire array electrodes. These Pd nanowire array electrodes were then rinsed three times with ethanol followed by deionized water.

Preparation of glucose oxidase bioanode

The surface of the Pd nanowire array electrodes was subsequently functionalized by treatment with 10 mM 3-(aminopropyl) trimethoxysilane (γ-APS) at 40°C for 30 minutes in order to introduce silane surface functionalities. After silanization, the Pd nanowire array electrodes were rinsed by sequential washing for 1 minute in ethanol,then in ethanol/water mixture (1:1, v/v). Finally, the Pd nanowire array electrodes were cured at 110°C for 20 minutes in a convection oven. This was followed by a derivatization step to create a continuous path of covalent bonding between the Pd nanowire electrode surfaces and the hydrogel composite membrane. The Pd nanowire array electrodes were incubated in the dark for 2 hours in 50 mM HEPES (pH=7.4) and 1 mM Acryloyl(polyethyleneglycol)-N-hydroxysuccinamide solution at room temperature. The derivatized Pd nanowire array electrodes were subsequently rinsed with 50 mM HEPES buffer.

Glucose oxidase enzyme solution with a concentration of 15 mg/mL was entrapped within a composite UV cross-linked HEMAbased hydrogel membrane material and subsequent deposition onto the Pd nanowire array electrodes. The monomer mixture comprised of HEMA, PEGMA, TEGDA in a mole ratio of 80:10:10. Glucose oxidase was dissolved in ethylene glycol: water (1:1 v/v) and then introduced into the monomer mixture. Photoinitiator DMPA (4 wt%) was then completely dissolved in the mixture and 3 μL of the enzyme-monomer mixture was applied to the Pd nanowire array electrodes. UV irradiation (2.3 W/cm2, 366 nm, UVP Model CX-2000) was performed for 20 minutes to polymerize the methacrylates. The PEGMA monomer was added to the hydrogel formulation to provide for long-term stabilization of membrane-immobilized glucose oxidase. This establishes PEG chains, set pendant to the polymer network, in the form of network supported polymer brushes. PEG chains are well known to stabilize proteins, preventing their denaturation and promoting long-term bioactivity [23].

The cyclic voltammetry experiments were performed on a BASi Epsilon at room temperature using a three-electrode cell. SEM measurements were performed with Hitachi SU70 to characterize the surface structure of the deposited Pd nanowires.

Results and Discussion

The physical appearance and surface characteristics of the Pd nanowire array electrodes were studied with an SEM. Figure 2 illustrates the typical SEM image of the free standing Pd nanowire arrays. As can be seen, highly ordered Pd nanowires were electrodeposited into the pores of the AAO template, upon completely etching away the AAO template. The average diameter of the nanowires is about 64.28 nm with a symmetric distribution. These nanowires are rod-like, uniform and vertically aligned on the electrode surface. The average length of the nanowires is 5.57 μm. The length of these Pd nanowires is much longer than those previously reported [15,19] because longer deposition time was necessary due to the depth of the AAO template. The Pd nanowire length is an important factor for the performance of the bioanode since it provides a larger electroactive surface area, thus resulting in higher catalytic capability of the glucose oxidase bioanode. The resulting hydrogel composite membrane on the Pd nanowire arrays (Figure 3) displays a marked difference in surface characteristics. This indicates clearly that the hydrogel composite membrane can be effectively integrated with the Pd nanowire array electrode surfaces through surface functionalization and crosslinking. The underlying Pd nanowire array electrode maintains high surface area after coating with hydrogel composite membrane.

biosensors-bioelectronics-micrograph-electrodeposited-nanowires

Figure 2: SEM micrograph (cross-section) of electrodeposited Pd nanowires from ammoniacal solution at a potential of -600 mV vs. Ag/ AgCl and t = 8 h using AAO template.

biosensors-bioelectronics-micrograph-morphology-bioanode

Figure 3: SEM micrograph of the morphology of the bioanode.

The characteristic Cyclic Voltammograms (CVs) of the bare Pd nanowire array electrodes and hydrogel composite modified Pd nanowire array electrodes responses were measured in the presence of 100 mM phosphate buffer (pH = 7.4) at the scan rate of 2 mV s-1. Figure 4 shows the corresponding CV curves for the bare Pd nanowires and the hydrogel composite modified Pd nanowire array electrodes. There is a large observable faradaic current on the Pd nanowire array electrodes with an oxidation peak at +0.05 V along with a reduction peak at 0.55 V, which attributes to the reduction of palladium surface oxides. The CV of the hydrogel composite modified Pd nanowire array electrodes shows that a pair of oxidation and reduction peaks at +0.05 V and 0.55 V, respectively were obtained. This provides confirmation that the hydrogel composite membrane restricts the flow of dissolved O2 to the Pd nanowire arrays surfaces, thereby resulting in small electrocatalytic activity for Pd surface oxide.

biosensors-bioelectronics-phosphate-buffer-nanowires

Figure 4: CVs of 100 mM phosphate buffer (pH = 7.4) at (----) bare Pd nanowires and (_____) hydrogel composite modified Pd nanowire array electrodes. Scan rate: 2 mV s-1.

The CVs for hydrogel composite modified Pd nanowire array electrodes responses were measured in the presence of 5 mM glucose substrate (pH = 7.4) at different scan rates (Figure 5). With increasing scan rates, the peak-to-peak separation and the observed linear relationship between the peak currents (Ipa and Ipc) and the scan rate (ν) from 2 to 800 mV s-1 in the insert of (Figure 3) illustrate that the redox process of glucose oxidase in this hydrogel composite membrane is a reversible process and is in agreement with the typical surface-confined process.

biosensors-bioelectronics-hydrogel-composite-bioanode

Figure 5: CVs of hydrogel composite modified Pd nanowire array bioanode in 5 mM glucose (pH = 7.4) at various scan rates. The scan rate is 2, 5, 10, 25, 50, 100, 200, 400, 599, 800 mV s-1 (from inner to outer). Insert: Plot of peak currents vs. scan rate.

The resulting hydrogel composite modified Pd nanowire array electrodes exhibited good electrocatalysis toward the oxidation of glucose. The CVs for the hydrogel composite modified Pd nanowire array electrodes responses were measured in the absence of glucose substrate and at glucose concentrations of 1, 3, 5 and 13 mM under physiological conditions at the scan rate of 2 mV s-1 (Figure 6). The oxidation current became larger and larger with increased concentration of glucose as a result of the oxidation of glucose to gluconic acid. The amperometric response reached saturation in the presence of glucose concentration greater than 13 mM. The calibration curve corresponding to the amperometric response (Figure 6) has a linear dynamic range from 1 mM to 13 mM (r = 0.978). The current density and power density for glucose oxidation at 5 mM glucose concentration, which is in the normal range of glucose concentration in the bloodstream is 851 μA cm-2 and 1.2 mW cm-2, respectively. This demonstrates that the Pd nanowire array electrodes promote the number of electroactive sites for the oxidation of glucose. These results further demonstrate that the glucose oxidase Pd nanowire array bioanode exhibits higher electrocatalytic activities at physiologic conditions, which directly improves glucose biofuel cell efficiency.

biosensors-bioelectronics-hydrogel-nanowire-calibration

Figure 6: CVs at the hydrogel composite modified Pd nanowire array bioanode in various concentrations of glucose: 1, 3, 5 and 13 mM from inner to outer. Insert: Calibration curve (R = 0.978). Scan rate of 2 mV s-1.

Conclusion

The major driving forces for the development of glucose based biofuel cells is energy sources for biomedical implantable devices. 5.57 μm long palladium nanowires with an average diameter of 64.28 nm were successfully electrodeposited using AAO template electrodeposition method. The hydrogel composite modified Pd nanowire arrays exhibited good electroactivity toward the oxidation of glucose. The hydrogel composite membranes achieved the direct electron transfer of redox enzyme, thereby not only demonstrating its potential to be used as a bioanode in glucose based biofuel cells, but also can be extended to biosensors.

Acknowledgements

The authors will like to thank Tim Buckheit, UMBC Microfabrication Cleanroom Manager and Dr. Wen-An Chiou at the Nanoscale Imaging, Spectroscopy and Properties Laboratory at the University of Maryland, College Park.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Relevant Topics

Article Usage

  • Total views: 12089
  • [From(publication date):
    October-2012 - May 20, 2018]
  • Breakdown by view type
  • HTML page views : 8284
  • PDF downloads : 3805
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2018-19
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2018 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
Leave Your Message 24x7