Previous Page  14 / 22 Next Page
Information
Show Menu
Previous Page 14 / 22 Next Page
Page Background

Notes:

Page 68

Euro Biotechnology 2016

November 07-09, 2016

Volume 6, Issue 7(Suppl)

J Biotechnol Biomater

ISSN: 2155-952X JBTBM, an open access journal

conferenceseries

.com

November 07-09, 2016 Alicante, Spain

12

th

Euro Biotechnology Congress

Rosario R Martinez Garcia et al., J Biotechnol Biomater 2016, 6:7(Suppl)

http://dx.doi.org/10.4172/2155-952X.C1.065

Performance of the AbSolute® High Cap resin in the Nimotuzumab capture step

Rosario R Martinez Garcia, Yvan Ruland, Sanndy Shen, Zhao Gang and Miguel A Arias

The Center for Molecular Immunology, Cuba

P

rotein A is the affinity chromatography ligand of choice for first-step capture in the purification of mAbs as its high

selectivity gives excellent purity plus high yields and also functions as the key volume reduction step in the process since

Protein A concentrates the product stream. The relatively high cost of these resins leads to consider different operational

strategy as evaluate protein A matrixes with better performance in dynamic binding capacity at high flow rates. Recently a new

Protein A ligand, AbSolute® High Cap (AbSolute HC), was introduced by Novasep Company that is modified with respect to

high binding capacity at higher velocities. This study investigated the performance of AbSolute HC resin during Nimotuzumab

capture by measuring its DBC at different flow rates and feed concentrations at lab scale. AbSolute HC data were also compared

with Mab Select SuRe, current affinity gel used in the purification process. The process conditions were adjusted including the

maximum speed for all steps with an assessment of impact on Nimotuzumab purity using AbSolute HC. In addition the impact

of loading amount on aggregates formation with this media and the resin lifetime were evaluated. The results showed better

DBC at 10% on AbSolute HC than Mab Select Sure, with a higher DBC at 10% on Absolute HC with IgG concentration at 2

g/L than 0.13 g/L. No significant loss of purity or yield for speeds until 1000 cm/h for all steps was obtained using AbSolute HC

resin. The lifetime of the media was tested up to 200 cycles with suitably results using NaOH and PAB solution.

Biography

Rosario R Martinez Garcia is a Chemical Engineer graduated in 1993 at High Polytechnic Institute Jose A. Echeverría (ISPJAE). Cuba. He has obtained his Master

of Science degree in Biotechnology Process (1999). Since 1993, he has been working in the Biotechnology field from 1997 at Center of Molecular Immunology

(CIM). He has participated in many postgraduate courses and training related with different themes of biotechnology and its application for the industry. Presently,

he is the Chief of Department of Plant Vaccines at CIM.

rosario@cim.sld.cu