alexa Ballooning mitral valve syndrome | Brazil | PDF | PPT| Case Reports | Symptoms | Treatment

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Ballooning Mitral Valve Syndrome

  • Share this page
  • Facebook
  • Twitter
  • LinkedIn
  • Google+
  • Pinterest
  • Blogger
  • Ballooning mitral valve syndrome

    Stenosis means narrowing of an opening, such as a heart valve. Stenosis of the mitral valve limits the forward flow of blood from the left atrium to the left ventricle. This may cause a back-up of blood and fluid in the lungs. Mitral stenosis most commonly develops many years after a person has had rheumatic fever, although many patients diagnosed with mitral stenosis don't recall ever having the illness.

  • Ballooning mitral valve syndrome

    Causes: Diagnosed with mitral stenosis don’t recall ever having the illness. During rheumatic fever, the valve becomes Mitral stenosis most commonly develops many years after a person has had rheumatic fever, although many patients inflamed. Over time, the leaflets of the inflamed valve stick together and become scarred, rigid and thickened, limiting its ability to open completely.

    Symptoms: Many of the symptoms of mitral stenosis, such as shortness of breath and fatigue, result from a back-up of blood in the lungs. Other symptoms of mitral stenosis may include quick weight gain; weakness; dizziness; swelling in the ankles, feet and/or abdomen (edema); and/or heart palpitations (irregular heartbeat).

  • Ballooning mitral valve syndrome

    Treatment: A balloon valvotomy is the preferred treatment for mitral valve stenosis. It is a procedure that widens the mitral valve so that blood flows more easily through the heart. A balloon valvotomy is a minimally invasive procedure. A doctor uses a thin flexible tube (catheter) that is inserted through an artery in the groin or arm and threaded into the heart. When the tube reaches the narrowed mitral valve, a balloon device located on the tip of the catheter is quickly inflated. The narrowed or fused mitral valve leaflets are separated and stretched open as the balloon presses against them. This process increases the size of the mitral valve opening and allows more blood to flow from the left atrium into the left ventricle.

  • Ballooning mitral valve syndrome

    Statistics: The Student t test was used for the comparison of continuous variables between group I (PBMV) and group II (MVC) and between pre- and postvalvuloplasty in each group. The Fischer exact test was utilized for comparison of the demographic data between the two groups. A value p < 0.05 was selected as the level of statistical significance. Percutaneous balloon mitral valvuloplasty was successful in 95% of patients, as evaluated by the Gorlin formula in the catheterization laboratory, and in 90.5%, as evaluated by the pressure half-time method 48 h after the procedure. Two patients had partial success in that their mitral valve area did not increase to >1.5 cm2.

Expert PPTs

Speaker PPTs

 

High Impact List of Articles

Conference Proceedings

adwords