Research Article

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

Nitin goel1, Shilpa2, Shashi yadav2
  1. Assistant Professor, Dept. of E.E, YMCA University of Science & Technology, Faridabad, India
  2. PG Student [PSD], Dept. of E.E, YMCA University of Science & Technology, Faridabad, India
Related article at Pubmed, Scholar Google
 

Abstract

The UPFC is a member of the FACTS family with very attractive features and it is a solid state controller which can be used to control active and reactive power flow in a transmission line. In this paper the performance of Unified Power Flow Controller (UPFC) is investigated in controlling the flow of power over the transmission line. This research deals with simulation of transmission line using UPFC to improve the real and reactive power flow control through a transmission line. In this research paper a Simulink Model is considered with UPFC model to evaluate the performance of a single and double transmission line systems (22/6.6) kV. In the simulation study, the UPFC models ease the real time control and dynamic compensation of AC transmission system. It should be consider as real and reactive power compensation, capable of independently controlling voltage profile as well as the real and reactive powers in the line. The simulation model is tested for single and double transmission line systems with and without UPFC model in MATLAB/SIMULINK environment. By using a UPFC the oscillation introduced by the faults, the rotor angle and speed deviations can be damped out quickly than a system without a UPFC. It is also shown that a UPFC can control independently the real and reactive power flow in a transmission line.c

Keywords

Share This Page

Additional Info

Loading
Loading Please wait..
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords