Dersleri yüzünden oldukça stresli bir ruh haline sikiş hikayeleri bürünüp özel matematik dersinden önce rahatlayabilmek için amatör pornolar kendisini yatak odasına kapatan genç adam telefonundan porno resimleri açtığı porno filmini keyifle seyir ederek yatağını mobil porno okşar ruh dinlendirici olduğunu iddia ettikleri özel sex resim bir masaj salonunda çalışan genç masör hem sağlık hem de huzur sikiş için gelip masaj yaptıracak olan kadını gördüğünde porn nutku tutulur tüm gün boyu seksi lezbiyenleri sikiş dikizleyerek onları en savunmasız anlarında fotoğraflayan azılı erkek lavaboya geçerek fotoğraflara bakıp koca yarağını keyifle okşamaya başlar

GET THE APP

256-Slice Coronary Computed Tomography Angiography Using Low Tube Voltage of 100 KV

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

256-Slice Coronary Computed Tomography Angiography Using Low Tube Voltage of 100 KV

Purpose: To evaluate the image quality and radiation dose of 100 kV with 1000 mAs retrospective electrocardiography (ECG)-gated CCTA protocol, compared to the standard protocol of 120 kV with 800 mAs retrospective ECG-gated CCTA. Material and Methods: We divided 70 patients into two, a reduced dose group with 35 patients (18 M, 17 F; Mean age 56.94 ± 11.51 years) were examined by 100-kV with 1000 mAs retrospective ECG-gated CCTA, and another as a standard group of 35 patients (21, 14 F; Mean age 54.03 ± 9.81 years) were examined by 120-kV with 800 mAs retrospective ECG-gated CCTA. The two blinded radiologists analyzed the image quality of the coronary arteries independently and they accessed subjective and objective image quality. The radiation dose was also measured as effective radiation dose [ED] and was calculated using CT dose volume index [CTDIvol.], dose-length product [DLP] and conversion coefficient for chest (conversion factor k=0.014 mSv mGy-1cm-1). Results: Although the objective image quality of the 100-kV with 1000 mAs was significantly better than the 120- kV with 800 mAs (mean SNR, 36.65 ± 2.95 vs. 33.47 ± 3.86, P<0.0001; mean CNR, 34.27 ± 2.92 vs. 30.62 ± 3.90, P<0.0001). There was no significant variation in the subjective image quality between two groups (mean image score, 4.54 ± 0.37 vs. 4.56 ± 0.25 for radiologist 1, P = 0.781; 4.52 ± 0.25 vs. 4.56 ± 0.25 for radiologist 2, P=0.486). The radiation dose was found to be reduced by 28% with the 100-kV/1000 mAs protocol than with the 120-kV/800 mAs retrospective ECG-gated CCTA (7.87 ± 0.59 vs. 10.95 ± 1.67 mSv, P<0.0001). Conclusion: The protocol of low tube voltage CCTA using 100 kV/1000 mAs retrospective ECG-gated shows significant reduction of the radiation dose without disturbing the subjective image quality of CCTA.

Sharma B (2015) 256-Slice Coronary Computed Tomography Angiography Using Low Tube Voltage of 100 KV. OMICS J Radiol 4:180. doi: 10.4172/2167-7964.1000180

  • Share this page
  • Facebook
  • Twitter
  • LinkedIn
  • Google+
  • Pinterest
  • Blogger
Top