alexa Analysis of STATCOM Controlled PMSG Based on Shore Win
ISSN ONLINE(2278-8875) PRINT (2320-3765)

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article

Analysis of STATCOM Controlled PMSG Based on Shore Wind Farm and Off Shore Wind Farm for Dynamic Stability Improvement

Srinivasa acharya1 , B.Srinivasa Rao 2
  1. P.G Student, Dept. of EEE, Aditya Institute Of Technology And Management, Tekkali , Srikakulam (Dist),A.P, India 1
  2. Associate professor, Dept. of EEE, Aditya Institute Of Technology And Management, Tekkali , Srikakulam (Dist),A.P, India 2
Related article at Pubmed, Scholar Google
 

Abstract

This paper deals with the development of a Mat lab-simulink model of a new proposed scheme for grid connected off shore wind farm (OWF) and marine current farm (MCF) on a static synchronous compensator (STATCOM). The purpose of this simulation Model to getting better damping enhancement and voltage control. An equivalent Doubly fed Induction Generator is used here to operate the Off shore wind farm while an equivalent Permanent magnet Synchronous Generator is used to operate the marine current farm. The PMSG is used to guide for an equivalent marine current turbine and the DFIG is used to guide for an equivalent Wind turbine. To design a damping controller for this proposed scheme model control theory is used here for getting the effective characteristics. The STATCOM controller plays an important role here. A frequency-domain approach based on a linearized system model using Eigen value techniques and a time-domain scheme based on a nonlinear system model subject to various disturbances are both employed to simulate the effectiveness of the proposed control scheme. It can be concluded from the simulated results that the proposed STATCOM joined with the designed damping controller is very effective to Balance the studied system under disturbance conditions. The proposed scheme of this AC bus system can easily control the voltage fluctuations.

Keywords

Share This Page

Additional Info

Loading
Loading Please wait..
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords