alexa Pandian's dc-dc Boost converters for Solar Panels using
ISSN ONLINE(2278-8875) PRINT (2320-3765)

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article

Pandian's dc-dc Boost converters for Solar Panels using Twisted Multi wire Transmission Line Transformers: High gain up to 7.4, and no need for additional MPPT control circuits

 
To read the full article Peer-reviewed Article PDF image

Abstract

A dc to dc Boost converter with a single inductor limits the voltage gain due to stray resistances in the inductor to about 1.5. This paper proposes dc to dc Boost converters by using twisted multiwire transmission line transformers specifically for solar panels. An output voltage of 225V in to 3260 ohms (dc voltage gain of about 7.4) was obtained by using a converter with a 5 wire transformer. The circuits work over a wide range of frequencies. Interestingly, the circuits exhibit a DCM mode of operation with good performance when the PWM ratio D is less than about 0.16. In this mode, the solar panel current charges the input capacitor for 84% of the PWM period and the energy in the capacitor is “converted” in the short 16% of the PWM period where the input current of the converter is many times the solar panel current. This results in a good performance of the solar panel without any need for additional MPPT control. The functioning of the converter is explained with waveforms and equations where it is shown that if the frequency of the converter is increased by a factor F, for optimum performance, the D value has to be increased by SQRT(F). The major feature of the proposed converters with solar panels is that no additional MPPT control is required. The efficiency of the converter was better than 81% when the 200W solar panel was tested in door at 12 Watts. The high dc gain possible with the proposed converters will reduce the wiring costs in solar panels and the copper loss in the solar panel wirings.

Share This Page

Additional Info

Loading
Loading Please wait..
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords