Dersleri yüzünden oldukça stresli bir ruh haline sikiş hikayeleri bürünüp özel matematik dersinden önce rahatlayabilmek için amatör pornolar kendisini yatak odasına kapatan genç adam telefonundan porno resimleri açtığı porno filmini keyifle seyir ederek yatağını mobil porno okşar ruh dinlendirici olduğunu iddia ettikleri özel sex resim bir masaj salonunda çalışan genç masör hem sağlık hem de huzur sikiş için gelip masaj yaptıracak olan kadını gördüğünde porn nutku tutulur tüm gün boyu seksi lezbiyenleri sikiş dikizleyerek onları en savunmasız anlarında fotoğraflayan azılı erkek lavaboya geçerek fotoğraflara bakıp koca yarağını keyifle okşamaya başlar

GET THE APP

Journal of Analytical & Bioanalytical Techniques - Comments on: The Application of Visible Absorption Spectroscopy to the Analysis of Uranium in Aqueous Solutions
ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
Open Access

Like us on:

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Comments on: The Application of Visible Absorption Spectroscopy to the Analysis of Uranium in Aqueous Solutions

Rathore DPS*
Atomic Minerals Directorate for Exploration and Research, Department of Atomic Energy, Jaipur, Rajasthan, India
*Corresponding Author: Rathore DPS, Atomic Minerals Directorate for Exploration and Research, Department of Atomic Energy, Jaipur, Rajasthan, India, Tel: 01412793598, Email: dpsr2002@yahoo.com

Received: 01-Nov-2017 / Accepted Date: 22-Nov-2017 / Published Date: 25-Nov-2017 DOI: 10.4172/2155-9872.1000389

Abstract

Comments on the application of visible absorption spectroscopy to the analysis of uranium in aqueous solutions are presented. This manuscript is lacking in update of literature survey on the analysis of uranium in aqueous solutions in concentrates. There is nothing new innovation contained in this publication. An update on a comparative analytical performance of their proposed application of visible absorption spectroscopy to the analysis of uranium in aqueous solutions in concentrates with those other reported analytical methods will give a better understanding of the developed analytical protocol. Application of Differential technique in spectrophotometry (DTspectrophotometry) /laser-/LED-induced fluorimetry (DT-LIF/DT-LED-LIF)/ICP-OES (DT-ICP-OES) has inherent high metrological quality and warrants its introduction as a relative reference measurement procedure.

Keywords: Uranium concentration analysis; Uranyl spectroscopy; Visible absorption spectroscopy; Differential spectrophotometry; Laser fluorimetry; Uranium concentrates

Comments

I have read this paper [1] and all the cited references in this manuscript. I would like to share some of my observations on this manuscript which may be useful for future research and a meaningful publication.

The authors claim in the abstract of the paper quote “Through assay analysis into an excess of 1 M H2SO4 at fixed temperature a technique has been developed for uranium concentration analysis by visible absorption spectroscopy over an assay concentration range of 1.8-13.4 mgU/g. Once implemented for a particular spectrophotometer and set of spectroscopic cells this technique promises to provide more rapid results than a classical method such as Davies-Gray (DG) titration analysis” unquote, the statement quoted in the manuscript appears misleading. This manuscript is lacking in update of literature survey on the analysis of uranium in aqueous solutions in concentrates. Moreover, there is nothing new information contained in this publication. The wellknown Davies and Gray titrimetric method for uranium [2], which permits the accurate determination of uranium in the presence of large quantities of impurities, including several modifications reported in the Davies and Gray’s method [3-5].

In addition to, there are interesting publications on rapid uranium concentration analysis techniques in concentrates, such as, the determination of uranium by high-precision spectrophotometry [6], Differential Spectrophotometric determination of uranium and niobium [7], Differential spectrophotometric method for determination of uranium by measuring absorbance using aqueous uranyl sulfate solutions at 418 nm [8], Determination of uranium in uranium concentrates [9], and application of differential technique in laser-induced fluorimetry for the direct, fast, accurate and precise determination of uranium in samples of diverse matrices of mineralized rocks [10], concentrates and other U-rich materials [11] over a dynamic range of concentrations >0.01% uranium.

The use of a "Differential Technique (DT)" in laser induced fluorimetry (LIF) is different to the standard procedure recommended by the instrument's manufacturer- the Scintrex UA-3 Uranium Analyser (Scintrex Limited, Concord, Ontario, Canada), i.e., two techniques of measurement, first, “measurement by external standard” (calibration graph) and second, “measurement by internal standard” (standard additions). The application of the differential technique in laser-induced fluorimetry is based on comparison of the fluorescence of the standard with a sample of similar but unknown concentration on the same sample weight basis by the use of an appropriate fluorescence enhancing reagent [10]. The theory for selecting the appropriate reference standard concentration to obtain the maximum precision possible in any given analysis has been used in laser induced fluorimetry and has been described in detail [10]. It was very interesting to note that in practice, the accuracy and precision of differential technique (DT) was found to be comparable with those obtained from differential spectrophotometric technique as well as to the classical titrimetry and gravimetric methods. Since differential technique (DT) fulfills the essential requirements of both equipment and method calibration, it is, therefore, a self-standardized methodology by using standards of accurately known concentrations, such as, certified reference materials [10-15]. In principle, laserinduced fluorimetry is an ideal technique for the very accurate determination of uranium by the use of appropriate fluorescenceenhancing reagents and methodology depending upon concentration of uranium and sample matrices [10-15]. The simplicity, rapidity, free from matrix effects, no separation steps, minimum generation of radioactive analytical waste, maximum throughput, cost-effectiveness, accuracy, high precision, comparability and traceability are the significant features of the differential technique [10-15]. In general, Differential technique in spectrophotometry [6-8] /laser fluorimetry [10-15]/ICP-OES [16] has high metrological quality and warrants its introduction as a ‘reference measurement procedure’ [15,16] for determination of total uranium in ores, certification of reference materials, core assay, beneficiation products and other diverse applications in nuclear fuel cycle.

Differential spectrophotometry is based on measuring the absorbance of the test solution against a standard of accurately known concentration instead of a reagent blank or pure solvent. In this way the error in measurement is confined to the difference in the two concentrations and so can be minimized [15]. In the differential technique, the precision of results is materially improved, if a relative rather than absolute concentration is determined. The most important achievement of differential spectrophotometric methods is the gain in precision of results to a level of 0.1-0.5% coefficient of variation, which was equal the precision obtained by classical gravimetric or titrimetric methods, and thus enable the use of easy-to-operate spectrophotometers for the determination of the main components of a given sample with appropriate scale expansion by placing cuvettes containing solutions of suitable concentrations in the cell compartment of the instrument, and adjusting the transmittance scale (in older instruments) with them [17]. A number of papers approach the method in connection with problems of error calculation of spectrophotometric measurements. Hiskey in his papers presented a thorough theoretical and practical description of the differential technique often called transmittance ratio method or precision spectrophotometry, reviewing at the same time the existing practical applications at that time [18,19]. Later a more general view point was presented by Reilley and Crawford about various possibilities of carrying out differential spectrophotometric measurements, which substantially differ from each other [20,21]. A review published by Svehla on the applications of differential spectrophotometry connected mainly with the larger concentrations of metals and organic substances, is commendable [22]. It deals with the principles of various methods of differential spectrophotometry, practical problems connected with the measurements and reviewed analytical applications reported till the period of review. Rapid differential spectrophotometric methods were reported for the determination of high percentages of nickel, uranium, cobalt, aluminium, beryllium, chromium, copper, erbium, manganese, molybdenum, neodymium, niobium, platinum, plutonium, praseodymium, samarium, silver, tantalum, titanium, zirconium, fluoride, cyanide, phosphate, acetazolamide, hydrochlorothiazide and other organic substances. Several comprehensive schemes of analysis detailing so-called ‘rapid methods’ were published generally restricted to the determination of the major elements, of which that of Shapiro and Brannock can be regarded as the most authoritative [23]. In fact, it is the designing of experimental procedure for calibration of instrument as well as the whole methodology for silica determination to bring the final absorbance of the comparison standards in the region of least photometric error. An orthogonal function method has been applied to the differential spectrophotometric determination of acetazolamide and hydrochlorothiazide in tablets [24]. A precision spectrophotometric determination of chromium in chromite ores and ferro-chrome has been reported [25]. The results are in good agreement with, and of comparable precision to, published data and to those obtained by titrimetric assay.

Conclusion

Differential Technique in spectrophotometry(DTSpectrophotometry)/ laser-induced fluorimetry/LED fluorimetry (DTLIF/ DT-LED-LIF) and in inductively coupled plasma emission spectrometry (DT-ICP-OES) has emerged as a technique with traceability andwarrants its introduction as a relative reference measurement procedure. Over the years, the application of differential technique will continue to grow for more reliable measurement of uranium in rocks, minerals, and concentrates with higher productivity to fulfill the mission and mandate in uranium processing industries.

References

  1. Colletti LM, Copping R, Garduno K, Lujan EJW, Mauser AK, et al. (2017) The application of visible absorption spectroscopy to the analysis of uranium in aqueous solutions. Talanta 175: 390-405.   
  2. Davies W, Gray W (1964) A rapid and specific titrimetric method for the precise determination of uranium using iron(II) sulphate as reductant. Talanta 11: 1203-1211.
  3. Florence TM, Pakalns P (1970) Proceedings of a Symposium on the Analytical Chemistry of U & Th, Lucas Heights, Sydney, AAEC/TM 552.
  4. Walker CR, Vita OA (1970) The precise determination of uranium in impure uranyl nitrate and uranium oxides. Anal Chim Acta 49: 391-400.
  5. RT Chitnis, Kulkarni RT, Rege SG, Mukherjee A (1978) Volumetric method for the determination of uranium in the active process solutions. J Radioanal Chem 45: 331-339.
  6. Bacon A, Milner GWC (1956) The determination of uranium by high-precision Spectrophotometry. Analyst 81: 456-469.
  7. Banks CV, Burke KE, O'Laughlin JW, Thompson JA (1957) Differential spectrophotometric determination of uranium and niobium. Anal Chem 29: 995-998.
  8. Susano CD, Oscar Menis, Talbott CK (1956) Differential Spectrophotometric Method for Determination of Uranium.  Anal Chem 28: 1072-1075.
  9. Guest RJ, Zimmerman JB (1955) Determination of uranium in uranium concentrates. Anal Chem 27: 931-936.
  10. Rathore DPS, Tarafder PK, Kayal M, Kumar M (2001) Application of a differential technique in laser-induced fluorimetry: simple and a precise method for the direct determination of uranium in mineralised rocks at the percentage level.  Anal Chim Acta 434: 201-208.
  11. Rathore DPS, Kumar M (2004) Analytical applications of a differential technique in laser-induced fluorimetry: accurate and precise determination of uranium in concentrates and for designing microchemielectronic devices for on-line determination in processing industries. Talanta 62: 343-349.
  12. Rathore DPS (2007) Trends in the Methods of Measurement in Analytical Chemistry. Explor Res at Miner 17: 145-149.
  13. Rathore DPS (2008)   Advances in technologies for the measurement of uranium in diverse matrices. Talanta, pp: 9-20.
  14. Rathore DPS, Kumar M, Tarafder PK (2012) Presentation of differential laser-induced fluorimetry as a reference measurement procedure for determination of total uranium content in ores and similar matrices. Accredit Qual Assur, pp: 1775-1784
  15. Murugesan P, Jain SK, Manjeet K, Tarafder PK, Rathore DPS (2013) Determination of total concentration of uranium in borehole core samples: Comparative studies using differential technique in laser-induced fluorimetry and ICP-OES. Explor Res at Miner 23: 137-144.
  16. Murugesan P, Khorge CR, Patwardhan AA, Manjeet Kumar, Tarafder PK, et al. (2014) Application of a differential technique in inductively coupled plasma emission spectrometry: presentation of a relative reference measurement procedure for the determination of total mass fraction of uranium in mineralised rocks and similar matrices. J Anal Spectrom 29: 1912-1917.
  17. Marczenko Z (1986) Separation and spectrophotometric determination of elements. Ellis Horwood Ltd., NY 2: 66.
  18. Hiskey CF, Young IG (1951) Principles of Precision Colorimetry. Anal Chem 23: 1196-1201.     
  19. Young IG, Hiskey CF (1951) Precision Colorimetry. Application to Determination of Manganese. Anal Chem 23: 506-508.
  20. Reilley CN, Crawford CM (1955) Principles of Precision Colorimetry. Anal Chem 27: 716-725.
  21. Shapiro L, Brannock W (1962) Rapid analysis of silicate, carbonate, and phosphate rocks. USGS Bull. 1144: 1-56.
  22. Elsayed MA, Elsayed YM, Abdine H (1980) Use of an orthogonal function in differential spectrophotometry.  Analyst 105: 222-229.
  23. Burns DT, Aziz MEMA (1980) Precision spectrophotometric determination of chromium in chromite ores and ferro-chrome. Analyst 105: 209-216.

Citation: Rathore DPS (2017) Comments on: The Application of Visible Absorption Spectroscopy to the Analysis of Uranium in Aqueous Solutions. J Anal Bioanal Tech 8: 389. DOI: 10.4172/2155-9872.1000389

Copyright: © Rathore DPS. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Top