Dersleri yüzünden oldukça stresli bir ruh haline sikiş hikayeleri bürünüp özel matematik dersinden önce rahatlayabilmek için amatör pornolar kendisini yatak odasına kapatan genç adam telefonundan porno resimleri açtığı porno filmini keyifle seyir ederek yatağını mobil porno okşar ruh dinlendirici olduğunu iddia ettikleri özel sex resim bir masaj salonunda çalışan genç masör hem sağlık hem de huzur sikiş için gelip masaj yaptıracak olan kadını gördüğünde porn nutku tutulur tüm gün boyu seksi lezbiyenleri sikiş dikizleyerek onları en savunmasız anlarında fotoğraflayan azılı erkek lavaboya geçerek fotoğraflara bakıp koca yarağını keyifle okşamaya başlar

GET THE APP

Journal of Analytical & Bioanalytical Techniques - Validation of Miniaturized Particulate-Matter Real-Time Samplers for Characterizing Personal Polycyclic Aromatic Hydrocarbon Exposure
ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
Open Access

Like us on:

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Validation of Miniaturized Particulate-Matter Real-Time Samplers for Characterizing Personal Polycyclic Aromatic Hydrocarbon Exposure

Beizhan Yan1*, Masha Pitiranggon1, James Ross1, Thomas Arthen-Engeland2, Andreas Stelter2 and Steven Chillrud N1
1Lamont-Doherty Earth Observatory of Columbia University, Palisades, NY, USA
2Bruker Daltonik GmbH, Bremen, Germany
*Corresponding Author: Beizhan Yan, Lamont-Doherty Earth Observatory of Columbia University, 61 Route 9W, Palisades, NY 10964, USA, Tel: 8453658448 Exn. 8453658155, Email: yanbz@ldeo.columbia.edu

Received: 29-Mar-2018 / Accepted Date: 06-Apr-2018 / Published Date: 11-Apr-2018 DOI: 10.4172/2155-9872.1000403

Abstract

This study validates the analysis of polycyclic aromatic hydrocarbons (PAHs) in microgram levels of particulate matter (PM) collected on filters by two low-flow rate, real-time monitors, microPEM™ and microAeth®. Particleassociated PAHs were analyzed by a coupling of a gas chromatograph to a sensitive, atmospheric-pressure laser ionization-mass spectrometer. Air particulate samples were collected over the course of one or two days in the living room of a fourth-floor apartment in New York City. Three types of samplers, the two aforementioned personal samplers and a high-flow rate pump (4 liters per minute), were operated side by side, and three samples of each type were collected during each sampling period. Intrasampler agreement as measured by relative standard deviation (RSD) was within 1% to 18%. After background subtraction, total PAH measured by all three sampler types had good agreement (R=0.99). This ability to accurately characterize personal PAH exposure in archived filters collected by these real-time samplers could provide additional important PAH exposure information that can benefit many environmental health studies using these monitors.

Keywords: Ionization; Pollutants; Chromatograph; Organic compounds; Mass spectrometry

Introduction

Miniaturized personal monitors are widely-accepted as the gold standard in air pollution exposure assessment. Traditional personal exposure monitors tend to be too cumbersome, noisy and laborintensive, and do not provide near-real-time measurements of key analytes, limiting most personal exposure studies to motivated cohorts of adolescents and adults [1,2]. Recently some miniaturized realtime personal monitors (e.g., microPEM™ by RTI International, Airbeam by HabitatMap, SidePak™ by TSI Incorporated) of particulate matter (PM) based on optical methods have been developed and used in epidemiology and environmental science studies [3-7]. The minimization of size, power, and noise, permits the use of these personal monitors on most individuals, including young children, the elderly and occupational workers, without disruption of their normal activities [8-10]. Among these personal monitors, several have a filter placed before the pump and the purpose of these filters varies. For example, the Teflon filter used in microPEM™ not only protects the pump from aerosol particles, but also can be gravimetrically weighed to calibrate the realtime data [5]. For microAeth®, a real time black carbon (BC) monitor, the optical attenuation caused by deposited particles on the filter is measured to determine BC loading [11]. If the filters in those samplers can be changed before each deployment, these spatial- and temporal- integrated samples have the potential to characterize PM exposure.

It will be highly cost-effective and scientifically important if key pollutant levels can be reliably quantified in these archived filters. However, minimization also inevitably results in a low flow pump that collects low mass particle samples. The AE51 model of a microAeth® unit is about 250 grams, 117 mm L × 66 mm W × 38 mm D in size and can be run at a flow rate of less than 0.2 liter per minute (LPM) with pumped air passing through a 3 mm spot on a filter strip [11,12]. The filter strip is made of T60 Teflon-coated borosilicate glass fiber filter material. The microPEM™ is about 240 grams, runs at a flow rate of 0.4-0.5 LPM with pumped air passing through a 25 mm outside diameter (OD), 3 micron porosity Teflo membrane filter (Pall Corp,Port Washington, NY). To extend battery life, both microAeth® and microPEM can be operated at a duty cycle <100% (i.e., pump and sensor can be cycled on and off at different time intervals). Depending on airborne PM level, the flow rate and duty cycles used during the sampling, the mass collected on filters can range from less than 1 μg to tens of μg. In contrast, traditional personal monitors typically collect 50 μg to a few hundred μg of PM2.5 since much higher flow rates (e.g., 4 LPM) are used [13]. In our lab, we have established analytical approaches to measure additional pollutants in filters collected by traditional samples, e.g., black carbon by an optical method (limit of detection (LOD) is about 0.5 μg) [14] and metals using X-ray fluorescence spectrometry [15] (LOD has not been determined in our lab). There has been no report on these measurements on filters collected by microAeth® and microPEM™.

One important class of pollutants is polycyclic aromatic hydrocarbons (PAHs) since numerous studies have suggested that exposures to PAHs are negatively associated with a variety of health outcomes including asthma symptoms [16]. Lines of evidence also suggest that certain PAH compounds are suspected or known carcinogens and mutagens [17,18]. PAH levels in New York City air samples are typically on the order of micrograms per gram of PM [19], therefore only picogram (10-12 gram) levels of PAHs can be collected by these miniaturized samplers. This pushes the analytical limits of most traditional mass spectrometry methods, which normally requires around 10 pg to be above detection limits for an individual PAH compound [20]. For a robust quantification, at least 30 pg of the compound would be needed, going by the convention that the limit of quantitation is three times the detection limit [21,22]. A novel analytical instrument, the gas chromatograph–atmospheric-pressure laser ionization-time of flight mass spectrometer (GC-APLI-TOFMS), was recently developed by Schiewek et al. [23], and to our knowledge it is the most sensitive instrument for aromatic compound analysis [24]. APLI is based on resonantly enhanced multi photon ionization at atmospheric pressure and selectively ionizes analytes with longer lifetimes in electronically excited states for the absorption of additional photons. The step-wise 2-photon absorption of APLI reduces the ionization of solvent and matrix molecules and therefore increases analytical selectivity and sensitivity [24-26]. This increased sensitivity would potentially allow for the measurement of PAHs collected by personal air samplers on the time range of a few hours at levels found in typical US cities and homes.

Our goal in this study is to validate the usage of archived filter collected by these miniatured samplers for PAH analysis. We will use this GC-APLI-TOFMS method to examine the specificity, sensitivity, and range necessary for accurate quantification of individual PAH compounds in the amounts collected on these mini-filter matrices. In this study, results from two different personal monitors (microPEM and microAeth®) will be compared to a conventional sampler.

Materials and Methods

Calibration

Our PAH calibration standards consisted of a mix of 16 parental PAHs (Restek (Bellefonte, PA) SV Calibration Mix, Cat. #31011), five alkyl-PAHs (2,6-dimethylnaphthalene, 2- methylphenanthrene, 3,6- dimethylphenanthrene, 1-methylpyrene, and 6- methylbenz[a]anthracene) from Accustandard (New Haven, CT), and two external standard compounds (acenaphthene-D10 and perylene- D12) from Accustandard (New Haven, CT). Six different concentrations of this mix were used for calibration, and each were spiked with equal amounts (1.0 × 105 femtograms/μl (fg/μl)), of five different internal standards: acenaphthylene- D8 (Cambridge Isotope Laboratories, Tewksbury, MA), anthracene-D10 (Supelco, St. Louis, MO), terphenyl-D14 (Supelco, St. Louis, MO), benzo[a]pyrene-D12 (SPEX CertiPrep, Metuchen, NJ), and indeno[c,d-1,2,3]pyrene-D12 (Cambridge Isotope Laboratories, Tewksbury, MA). The six different concentrations were 6.25, 12.5, 25, 50, 80, and 100 fg/μl. Calibration standards at each concentration were run in triplicate on GC-APLI. Calibration curves were made using averages of the triplicate runs.

Sample collection

Air particulate samples were collected over the course of eleven 24- hour sampling periods and one 48-hour sampling period in the living room of a fourth-floor apartment in the Upper West Side of Manhattan in New York City, NY. Three types of samplers were operated side by side and three samples of each type were collected during each sampling period. Two types of samplers collected PM2.5 on Teflon filters, one from a black box pump (BB) with conventional cyclone (model GK 2.05, BGI, Inc.) at 4 ± 0.4 L/min and the other from a microPEM (μPEM) personal exposure monitor (RTI International, Research Triangle Park, NC) operated at 0.4 ± 0.04 L/min. The third sampler was a microAeth® (μAeth) personal black carbon (BC) monitor (AethLabs, San Francisco, CA), which collected dust samples on Teflon- coated borosilicate glass fiber filters (T60) at 0.1 ± 0.01 L/min. With the exception of one μPEM that was excluded from the analysis here, the relative standard deviation of the flow rates measured at the start and end of each sampling period stayed within 0% to 7%. One field blank for each type of sampler was obtained by setting up the sampler as usual, but without turning on their respective pumps. All filters were pre-cleaned by dichloromethane in an ultrasonic bath prior to sampling.

PAH extraction

Organic extracts from each filter were obtained via ultrasonic extraction in 1 mL of 9:1 dichloromethane:methanol (v/v) for 60 minutes. Each sample was spiked with 10 ng of acenaphthene-d10 and perylene-d12 before extraction as external standards. Following extraction, each sample underwent silica column cleanup to remove polar organic compounds [27]. Each silica column consisted of 0.720 g of silica gel topped off with a thin layer of sodium sulfate. Dichloromethane was used as the eluent, and approximately 4 mL of eluent was collected from each column. The samples were then concentrated under N2 gas and spiked with an internal standard mix containing: acenaphthylene-d8, anthracene-d10, terphenyl-d14, benzo[a]pyrene-d12, and indenopyrene-d12. The conventional cyclone samples were spiked with 20 ng of the internal standard mix. All other samples were spiked with 10 ng of internal standard. Extracts were stored at 4°C until further analysis.

Analysis by GC-APLI

The organic filter extracts were analyzed using a Bruker 450-GC and a Compact time-of- flight mass spectrometer (Bruker Daltonics, Bremen, Germany). 2 μl of each sample were injected in splitless mode with the inlet temperature at 275°C. The GC column was a Restek Rxi- PAH column (40 m length, 0.18 mm ID, 0.07 μm df). The column oven was initially held at 40°C for 1 minute, then increased to 110°C at 40°C/min, held for 1 minute, increased again to 210°C at 37°C/min, where the ramp rate slowed to 3°C/min up to 260°C, finally ramping at a rate of 11°C/min up to 350°C, where it was held for 8.7 minutes. Helium was used as the carrier gas at a constant flow rate of 1.4 mL/ min. The mass spectrometer was operated with a GC-APLI II source in atmospheric pressure laser ionization mode, using a diode-pumped solid state (DPSS) laser (CryLas GmbH, Berlin, Germany) operated at 266 nm with a 200 Hz repetition rate and 60 μJ per pulse [28]. Masses 50-500 were scanned at an acquisition speed of 2 Hz. The capillary was set at -1000 V with an end plate offset of 0 V. Nebulizer gas was supplied at 3 bar, and the drying gas had a flow rate of 2.5 L/min at 250°C.

Results and Discussion

GC-APLI analysis and quantitation

GC-APLI proved to be a highly sensitive instrument for ultra-trace level measurement of PAHs in low mass PM samples collected from personal samplers (Figure 1), consistent with other reports [24,28]. Figure 1 shows a chromatogram of a typical PAH profile from a sample with anthropogenic contributions, as indicated by the typical pattern of methyl- and dimethyl- substituted phenanthrenes. Additionally, several isomers of benzofluoranthenes and dibenzanthracenes were properly separated in the chromatograms, indicating the variety of PAHs observed in these samples.

analytical-bioanalytical-techniques-chromatogram

Figure 1: Example extracted ion chromatogram (EIC) traces of target PAHs in GC-APLI chromatogram of a uAeth filter extract.

The analytical working range investigated was 6 to 100 fg/μl for 20 PAHs, although real the analytical working range is expected to be larger. Of those compounds that were above the detection limit, individual PAH concentrations were estimated to range from 0.086 fg/μl to 1800 fg/μl for μAeth samples and 3.1 fg/μl to approximately 1500 fg/μl for μPEM samples. This means that GC-APLI was able to detect individual PAHs down to 0.17 fg total on-column injection. Most conventional mass spectrometry methods need an on-column injection of 10 pg (1 × 104 fg) to overcome detection limits for individual PAHs [20]. Since the samples involved in this study pertain to particle-associated compounds, PAHs with m/z greater than 202 were the most relevant, and analysis was limited to these high molecular weight PAHs: 1-methylpyrene, benz[a]anthracene, chrysene, 6-methylbenz[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[ah]anthracene, benzo[ghi]perylene. The sum of these PAHs is referred to as TPAH in the remainder of this text.

The calibration curves for all PAHs used in sampler agreement analysis had r-squared values of 0.99 and above (Figure 2, Table S1). Indeno[c,d-1,2,3]pyrene was excluded due to issues with its calibration; it was eluting at the same retention time as its internal standard, indeno[c,d-1,2,3]pyrene-D12, which was present at a much higher concentration than indeno[c,d-1,2,3]pyrene in all calibration standards and samples. Signal disturbance from the internal standard may have resulted in unreliable peak quantification. See Supplemental Information for low molecular weight PAH and indeno[c,d-1,2,3]pyrene calibration results.

analytical-bioanalytical-techniques-calibration

Figure 2: Benzo[a]pyrene (BaP) calibration curve. All PAHs in the sampler validation analysis had an r-squared of 0.99 and above.

Sampler comparison

Due to time constraints and sample availability, 2-3 replicates of each sampler type from 4 sampling periods were selected to be analyzed on APLI. Background correction was performed on TPAH measurements from all samples by subtracting the TPAH measured on each samplers’ respective field blank. This background-corrected data is presented in Table 1. Due to the extremely low mass of PAHs (fg) collected onto the filters of miniaturized samplers, there are special requirements for obtaining reliable data: 1) a clean lab equipped with laminar flow hood fitted with HEPA filter to be used for filter handling, 2) a clean organic lab to handle solvents and PAH analysis, 3) subtracting the PAHs measured in field blank samples. Relatively high PAH background was observed in the T60 filter, and without background correction, PAH levels will be overestimated.

Date Replicate # TPAH by BB (pg/L) TPAH by uPEM (pg/L) TPAH by uAeth (pg/L)
3/29/2012 1 1.15E-01 1.05E-01 1.56E-01
3/29/2012 2 1.48E-01 1.15E-01 1.21E-01
3/29/2012 3 na na 1.16E-01
3/31/2012 1 2.57E-01 2.91E-01 3.04E-01
3/31/2012 2 2.61E-01 2.44E-01 2.59E-01
3/31/2012 3 na na na
04-03-2012 1 9.04E-02 9.15E-02 7.42E-02
04-03-2012 2 9.91E-02 1.13E-01 9.47E-02
04-03-2012 3 na na 7.00E-02
4/13/2012 1 1.77E-01 1.59E-01 1.65E-01
4/13/2012 2 1.72E-01 1.54E-01 1.28E-01

Table 1: TPAH measurements made by conventional black box pump (BB), microPEM (uPEM), and microAeth® (uAeth) in four different sampling periods

After background subtraction, side-by-side deployment of μAeth, μPEM, and BB samplers revealed excellent reproducibility of sampler replicates on each sampling day (Figure 3). Intrasampler agreement as measured by relative standard deviation (RSD) was within 1% to 18%. For BB pumps, the mean RSD for TPAH in each sampling period was 7% ± 4%, with a mean absolute standard deviation of 9 ± 5 fg/L. For μAeth personal samplers, the mean RSD for TPAH in each sampling period was 16% ± 1%, with a mean absolute standard deviation of 24 ± 4 fg/L. For μPEM personal samplers, the mean RSD for TPAH in each sampling period was 9% ± 3%, with a mean absolute standard deviation of 15 ± 7 pg/L.

analytical-bioanalytical-techniques-measurement

Figure 3: Comparison of TPAH concentrations by 3 different units,black box pump (BB), microPEM (uPEM), and microAeth® (uAeth). The points represent the mean TPAH measurement for each sampler on each sampling day with error bars representing the standard error of the mean. N=2 for every sampler on each sampling day except for the uAeth on 3/29/2012, 4/3/2012, and 4/13/2012, where N=3.

In addition to excellent intrasampler agreement, intersampler agreement was also very good. μPEM samples had PAH concentrations that were consistent with samples collected by conventional BB pumps (Figures 3 and 4), and TPAH for each sampling period (N=4) were highly correlated (R=0.99; slope ± SE=1.004 ± 0.09). The mean RSD of TPAH among μPEMs and conventional cyclones in each sampling period was 7% ± 2%, with a mean absolute standard deviation of 10 ± 2 fg/L. There is also a very high correlation of microAeth® TPAH and conventional pump TPAH (Figures 3 and 4) for each sampling period (R=0.99; slope ± SE=1.077 ± 0.08), and the mean RSD among microAeths® and conventional cyclones was 6% ± 2%, with a mean absolute standard deviation of 9 ± 3 fg/L. Excluding dibenz[a,h]anthracene and those compounds that were below detection limit, intersampler agreement was also decent when looking at individual PAH concentrations as measured by the different samplers (Table 2). Dibenz[ah]anthracene had some of the lowest mass loadings of all the high molecular weight PAHs in these samples; it is possible that these mass loadings were not high enough for reliable quantitation. Otherwise, mean RSDs among microAeths® and conventional cyclones ranged from 9% ± 3% for benzo[ghi]perylene to 29% ± 6% for benzo[a]pyrene. Similarly, among microPEMs and conventional cyclones, mean RSDs ranged from 9% ± 3% for benzo[ghi]perylene to 32% ± 13% for 1-methylpyrene.

analytical-bioanalytical-techniques-conventional

Figure 4: (A) the linear association of PAH measurements by microPEM personal samplers (uPEM) with conventional black box pumps (BB). Error bars represent the standard error of the mean TPAH measurements made by microPEM. (B) the linear association PAH measurements by microAeth® personal samplers (uAeth) with conventional black box pumps (BB). Error bars represent the standard error of the mean TPAH measurements made by microAeth®. Points at the origin represent field blanks.

  Black Box vs. microAeth Mean %RSD Black Box vs. microPEM Mean %RSD
1-Methylpyrene na 32 (13)
Benz[a]anthracene na 24 (7)
Chrysene na 16 (5)
6-Methylbenz[a]anthracene na na
Benzo[b]fluoranthene 25 (14) 25 (5)
Benzo[k]fluoranthene 22 (7) 13 (5)
Benzo[a]pyrene 29 (6) 11 (5)
Dibenz[ah]anthracene 109 (8) 56 (9)

Table 2: Mean percent relative standard deviations (standard error of the mean) for each individual PAH included in the sampler validation analysis.

In summary, this study validates the analysis of PAHs in archived PM samples collected by miniaturized personal exposure monitors if they have a filter to collect PM. Due to the low mass collected, a sensitive PAH analysis is required and our research shows that GCAPLI- TOFMS is a novel method for identifying and quantifying ultratrace- levels of PAHs. To our knowledge, there is no other instrument available with the ability to accurately measure PAHs at such low levels. The ability to accurately quantify personal PAH exposure would greatly strengthen any epidemiological study aiming to determine the health effects of airborne pollutant exposure. Future studies should consider minimum sampling times necessary to collect adequate sample mass for reliable quantitation by running samplers at variable sampling times.

Acknowledgements

This research was supported by the American Chemistry Council grant (LRI Project# 5093). Funding was also provided by the NIEHS Center for Environmental Health in Northern Manhattan (P30 ES009089) to establish the trace organic lab and NIH (U01 EB021983-01). This is Lamont-Doherty Earth Observatory (LDEO) contribution number XXXX.

References

  1. Chillrud SN (2005) Steel Dust in the New York City Subway System as a Source of Manganese, Chromium, and Iron Exposures for Transit Workers. J Urban Health Bull, NY Acad Med 82: 33-42.
  2. Chillrud SN, David E, James Ross M, Sonja Sax N, Pederson D, et al. (2004) Elevated Airborne Exposures of Teenagers to Manganese, Chromium, and Iron from Steel Dust and New York City’s Subway System. Environ Sci Technol 38: 732-737.
  3. Jiang R, Bell ML (2008) A Comparison of Particulate Matter from Biomass-Burning Rural and Non-Biomass-Burning Urban Households in Northeastern China. Environ Health Perspect 116: 907-914.
  4. Dutmer CM (2015) Accurate Assessment of Personal Air Pollutant Exposures in Inner- City Asthmatic Children. J Allergy Clin Immunol St Louis 135: 165.
  5. Zhang T (2017) Comparison of PM2.5 Exposure in Hazy and Non-Hazy Days in Nanjing, China. Aerosol Air Qual Res 17: 2235-2246.
  6. Sousan S, Koehler K, Hallett L, Peters TM (2017) Evaluation of consumer monitors to measure particulate matter. J Aerosol Sci 107: 123-133.
  7. Wang C (2016) Personal exposure to fine particulate matter and blood pressure: A role of angiotensin converting enzyme and its DNA methylation. Environ Int 94: 661-666.
  8. Lovinsky-Desir S (2016) Physical activity, black carbon exposure and airway inflammation in an urban adolescent cohort. Environ Res 151: 756-762.
  9. Rodes CE, Chillrud SN, Haskell WL, Intille SS, Albinali F, et al. (2012) Predicting adult pulmonary ventilation volume and wearing complianceby on- board accelerometry during personal level exposure assessments. Atmos Environ 57: 126-137.
  10. Lovinsky-Desir S (2014) Urban Adolescents Readily Comply with a Complicated Asthma Research Protocol. Clin Med Insights Med 8: 5-9.
  11. Cai J (2014) Validation of MicroAeth® as a Black Carbon Monitor for Fixed-Site Measurement and Optimization for Personal Exposure Characterization. Aerosol Air Qual Res 14: 1-9.
  12. Whyatt RM (2003) Contemporary-use pesticides in personal air samples during pregnancy and blood samples at delivery among urban minority mothers and newborns. Environ Health Perspect 111: 749-756.
  13. Yan B (2011) Validating a nondestructive optical method for apportioning colored particulate matter into black carbon and additional components. Atmos Environ 45: 7478-7486.
  14. Ngo NS, Gatari M, Yan B, Chillrud SN, Bouhamam K, et al. (2015) Occupational exposure to roadway emissions and inside informal settlements in sub-Saharan Africa: A pilot study in Nairobi, Kenya. Atmos Environ 111: 179-184.
  15. Rosa MJ (2011) Prenatal exposure to polycyclic aromatic hydrocarbons, environmental tobacco smoke and asthma. Respir Med 105: 869-876.
  16. Durant JL, Busby WF, Lafleur AL, Penman BW, Crespi CL (1996) Human cell mutagenicity of oxygenated, nitrated and unsubstituted polycyclic aromatic hydrocarbons associated with urban aerosols. Mutat Res Toxicol 371: 123-157.
  17. Nisbet ICT, LaGoy PK (1992) Toxic equivalency factors (TEFs) for polycyclic aromatic hydrocarbons (PAHs). Regul Toxicol Pharmacol 16: 290-300.
  18. Tonne CC, Whyatt RM, Camann DE, Perera FP, Kinney PL (2004) Predictors of personal polycyclic aromatic hydrocarbon exposures among pregnant minority women in New York City. Environ Health Perspect 112: 754-759.
  19. Crimmins BS, Baker JE (2006) Improved GC/MS methods for measuring hourly PAH and nitro-PAH concentrations in urban particulate matter. Atmos Environ 40: 6764-6779.
  20. Armbruster DA, Tillman MD, Hubbs LM (1994) Limit of detection (LQD)/limit of quantitation (LOQ): comparison of the empirical and the statistical methods exemplified with GC-MS assays of abused drugs. Clin Chem 40: 1233-1238.
  21. Nakashima S, Hayashi Y (2016) Determination of Detection Limits and Quantitation Limits for Compounds in a Database of GC/MS by FUMI Theory. Mass Spectrom 5: 1.
  22. Schiewek R (2007) Ultrasensitive Determination of Polycyclic Aromatic Compounds with Atmospheric-Pressure Laser Ionization as an Interface for GC/MS. Anal Chem 79: 4135-4140.
  23. Stader C, Beer FT, Achten C (2013) Environmental PAH analysis by gas chromatography–atmospheric pressure laser ionization–time-of-flight–mass spectrometry (GC- APLI-MS). Anal Bioana Chem 405: 7041-7052.
  24. Kauppila TJ, Kersten H, Benter T (2014) The Ionization Mechanisms in Direct and Dopant-Assisted Atmospheric Pressure Photoionization and Atmospheric Pressure Laser Ionization. J Am Soc Mass Spectrom 25: 1870-1881.
  25. Kauppila TJ, Kersten H, Benter T (2015) Ionization of EPA Contaminants in Direct and Dopant-Assisted Atmospheric Pressure Photoionization and Atmospheric Pressure Laser Ionization. J Am Soc Mass Spectrom 26: 1036-1045.
  26. Yan B, Abrajano TA, Bopp RF, Chaky DA, Benedict LA, et al. (2005) Molecular Tracers of Saturated and Polycyclic Aromatic Hydrocarbon Inputs into Central Park Lake, New York City. Environ Sci Technol 39: 7012-7019.
  27. Kersten H, Lorenz M, Brockmann KJ, Benter T (2011) Evaluation of the Performance of Small Diode Pumped UV Solid State (DPSS) Nd:YAG Lasers as New Radiation Sources for Atmospheric Pressure Laser Ionization Mass Spectrometry (APLI-MS). J Am Soc Mass Spectrom 22: 1063.

Citation: Yan B, Pitiranggon M, Ross J, Arthen-Engeland T, Stelter A, et al. (2018) Validation of Miniaturized Particulate-Matter Real-Time Samplers for Characterizing Personal Polycyclic Aromatic Hydrocarbon Exposure. J Anal Bioanal Tech 9: 403. DOI: 10.4172/2155-9872.1000403

Copyright: © 2018 Yan B, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Top