Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Factors Affecting Doses for Medical Staff in Orthopaedic Procedures Under Xrays Control

Maria A Staniszewska*

Department of Medical Imaging Techniques, Faculty of Biomedical Sciences and Postgraduate Education, Medical University of Lodz, Poland

Corresponding Author:
Staniszewska MA
Department of Medical Imaging Techniques
Faculty of Biomedical Sciences and Postgraduate Education
Medical University of Lodz, Poland
Tel: +48 42 272 58 03
E-mail: [email protected]

Received Date: May 10, 2017; Accepted Date: May 22, 2017; Published Date: May 29, 2017

Citation: Staniszewska MA (2017) Factors Affecting Doses for Medical Staff in Orthopaedic Procedures Under X-rays Control. Clin Res Foot Ankle 5:235. doi: 10.4172/2329-910X.1000235

Copyright: © 2017 Staniszewska MA. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Clinical Research on Foot & Ankle

Letter to Editor

Interventional medical procedures performed under X-rays control became very popular. Beside of cardiology and neurosurgery, they are implemented also in non-vascular fields, like urology, orthopaedy, gastroenterology, etc. In orthopaedic procedures fluoroscopy is used to control of surgery reconstructions. The ICRP recommendations [1] and Directive of EC [2] implemented as the legal rules in Poland [3] require to use at least 2 individual dosimeters by medical staff participating in interventional procedures (IR). Despite of that, orthopaedic teams are treated as low-risk staff and thus not always are properly monitored. Nevertheless, the need of control radiation risk for this group was proved by the results of dose measurements which were conducted by nearly 3 years (2012-2015) in the orthopaedic clinics of the 3 big hospitals in Lodz (Poland). The detail dosimetric control were submitted the members of medical teams performing osteosynthesis for limb fractures. Two methods were applied: intramedullary (more complicated) and remainder (easier to perform). Each team member was equipped in 4 dosimetric tools containing thermoluminescent dosimeters to measure the equivalent doses for the eyes, skin of the hand and the neck (outside of the shield) and to evaluate effective dose. All the procedures were performed under control of X-ray fluoroscopy. The C-arm units used for that were appropriate technical quality. (Material and methods of the measurements were already described in details [4].) The observations performed during the study were as follows. Although all X-ray devices have pulsed fluoroscopy mode any team did use it! Only in one clinic (the hospital No.2) dose rate was reduced to 50%. Additionally, no member of the teams wore the protective glasses and protective gloves (even the operator). The mean doses per one procedure for operator are given in table 1 below.

Hospital KAP [cGy.cm2]
(Average ± standard deviation)
Dose [mSv]
Effective
(trunk)
Equivalent for
Eyes Neck Skin on hand
1 586.6±396.5 0.019 0.042 0.034 0.366
2 246.9±199.2 ≈0.003 0.029 0.011 0.677
3 722.0±826.0 0.023 0.073 0.061 1.604

Table 1: The mean doses per one procedure for operator and Kerma Air Product (KAP) in the particular hospitals.

The most important conclusions resulting from the dosimetric measurements are following:

The equivalent doses for operator as the most exposed person are (0.029-0.073) mSv and (0.366-1.604) mSv per one procedure for the eyes and skin of the hand, respectively, Significantly higher are the doses during the procedures of intramedullary osteosynthesis (especially for operator) and also a higher impact to Kerma Air Product (KAP) arises from these significant correlation between KAP and equivalent doses for eyes and neck of operator was also found.

Finally, a maximum value of equivalent dose for eyes possible to collect by the operator during one year was evaluated and then compared to the lowered annual limit (i.e. 20 mSv) recommended by ICRP [1]. The result for Hospital No.3 was taken into account, i.e. 0.073 mSv per one procedure. Assuming the number of 300 procedures (mostly intramedullary osteosynthesis ones) are performed during one year by one operator, the maximal equivalent dose for his eyes achieves ≈22 mSv and exceeds the recommended limit of 20 mSv. Such risk can be significantly reduced if lower dose rate (like in Hospital No.2) and/or pulsed fluoroscopy are used , together with individual protective glasses.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Recommended Conferences

  • 5th International Conference on Physiotherapy
    Nov 27-28, 2017, Dubai, UAE

Article Usage

  • Total views: 232
  • [From(publication date):
    July-2017 - Nov 19, 2017]
  • Breakdown by view type
  • HTML page views : 186
  • PDF downloads : 46
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords