alexa Analysis and Preparation of Linaclotide by High Perform
ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
Open Access

Like us on:
OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article

Analysis and Preparation of Linaclotide by High Performance Liquid Chromatography

Yi-Shen Zhu*, Tao Feng, Yong-Qin Diao and Chun-Yan Tu

College of Biotechnology and Pharmaceutical Engineering, Nanjing Tech University, Nanjing 211816, China

*Corresponding Author:
Yi-Shen Zhu
College of Biotechnology and Pharmaceutical Engineering
Nanjing Tech University
Nanjing 211816, China
Tel: +8618900660563
Fax: +862558139910
E-mail: [email protected]

Received date: June 03, 2017; Accepted date: June 09, 2017; Published date: June 12, 2017

Citation: Zhu YS, Feng T, Diao YQ, Tu CY (2017) Analysis and Preparation of Linaclotide by High Performance Liquid Chromatography. J Anal Bioanal Tech 8:366. doi: 10.4172/2155-9872.1000366

Copyright: © 2017 Zhu YS, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

 

Abstract

Linaclotide, a synthetic peptide, is a guanylate cyclase-C (GC-C) agonist for treating irritable bowel syndrome with constipation and chronic idiopathic constipation. A simple, precise and selective RP-HPLC method for linaclotide analysis was developed and validated. Analysis was achieved with a SinoChrom ODS-BP column, mobile phase A and B comprised 30 mol·L-1 phosphate (pH 2.8) solution and acetonitrile respectively, gradient elution B% set to 7%?25% from 0 to 32 min and to 25% from 32 to 50 min, flow rate of 1.0 mL·min-1, oven temperature at 40?, injection volume of 20 µL, and UV detection wavelength at 214 nm. Method validation was carried out in linearity, LOD, LOQ, precision and stability. Modified method for linaclotide preparation on a preparative liquid chromatography was developed from the analytical method and applied successfully.

Keywords

Share This Page

Additional Info

Loading
Loading Please wait..
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords