Abstract

Background: Spinal cord stimulation (SCS) is a safe and effective treatment for refractory failed back surgery syndrome (FBSS). Two implantation procedures exist depending on the use of a surgical versus percutaneous lead. Percutaneous leads implantation is less invasive but the placement procedure requires a higher X-ray exposure. The new MRI compatible shielded percutaneous leads (Vectris®) appear to be stiffer and therefore seem to be easier to implant compared to unshielded percutaneous electrodes (Octad®). The aim of this study is to compare the radiation exposure between percutaneous shielded leads and percutaneous unshielded leads in SCS implantation.

Setting: Retrospective study.

Material and methods: 20 patients successively underwent SCS for FBSS. The first 10 patients were implanted with an Octad ® lead and the 10 following with a shielded Vectris ® lead. All patients were operated on by the same surgical team. In all cases, the same intra-operative X-rays device (Ziehm Vision 8000®) was used, with identical parameters aiming at a minimal X-rays exposure (pulse mode with 2 impulses/sec, and automatic mode for kVp and mAs).

Results: Fluoroscopy time was significantly lower in patients implanted with the Vectris® lead (mean: 99 seconds) compared to the Octad® lead (mean: 291 seconds) (p=0.0035). Subsequently, total patient X-rays exposure in the Vectris group (mean 592 cGycm2) was significantly lower than in the Octad® group (mean: 1899 cGycm2) (p=0.0005).

Conclusion: The use of MRI compatible shielded percutaneous leads significantly reduces the fluoroscopy time and the total X-ray exposure in SCS implantation.

To read the full article Peer-reviewed Article PDF image | Peer-reviewed Full Article image

Author(s): Nathalie Zaidman, Brice Constant, Cristo Chaskis and Laurence Abeloos*

Keywords

Low Back Pain, Spinal cord tumor, Knee pain

Share This Page

Additional Info

Loading
Loading Please wait..
 
 
 
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords