ISSN: 2161-0681

Journal of Clinical & Experimental Pathology
Open Access

Our Group organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)
Google Scholar citation report
Citations : 2975

Journal of Clinical & Experimental Pathology received 2975 citations as per Google Scholar report

Journal of Clinical & Experimental Pathology peer review process verified at publons
Indexed In
  • Index Copernicus
  • Google Scholar
  • Sherpa Romeo
  • Open J Gate
  • Genamics JournalSeek
  • JournalTOCs
  • Cosmos IF
  • Ulrich's Periodicals Directory
  • RefSeek
  • Directory of Research Journal Indexing (DRJI)
  • Hamdard University
  • EBSCO A-Z
  • OCLC- WorldCat
  • Publons
  • Geneva Foundation for Medical Education and Research
  • Euro Pub
  • ICMJE
  • world cat
  • journal seek genamics
  • j-gate
  • esji (eurasian scientific journal index)
Share This Page

Evaluation of whole blood viscosity and hematological data using scanning capillary tube viscometer in pigs

3rd International Conference and Exhibition on Pathology

Jun Koh, Jinmu Jung, Dongbin Lee, Kwangseon Oh, Junho Hwang, Haebeom Lee, Minsu Kim, Donghwan Lee and Namsoo Kim

Posters: J Clin Exp Pathol

DOI: 10.4172/2161-0681.S1.013

Abstract
Whole blood viscosity which is major determinants of hemorheology is associated with cardiovascular, endocrinal, and cerebral nervous disease. An acquiring accurate blood viscosity measurement has been major issues in clinical pathology not even in veterinary medicine, and new type of scanning capillary tube viscometer proposes solution with continuous measurement of viscosity over whole range of shear rates. The objective of this study is to evaluate the normal range of whole blood viscosity and the correlation between whole blood viscosity and hematological data. The blood samples were collected from jugular vein by venipuncture in pigs (n=130). Whole blood viscosity measured within 4 hours after collection using scanning capillary tube viscometer. Scanning capillary tube viscometer which is capable of measuring yield stress and viscosity of whole blood continuously over a wide range of shear rates from 1s -1 to 1000s -1 calculates viscosity using Casson fluid model. Mean diastolic and systolic blood viscosity of pigs were 34.66±7.84 and 4.88±0.85 respectively. Diastolic and systolic blood viscosity had a statistical significant correlation with the level of leukocyte (WBC), erythrocyte (RBC), hemoglobin (HGB), hematocrit (HCT), fibrinogen, alkaline phosphatase (ALP) and glucose in hematological examination (p<0.01). There were statistical significant differences of blood viscosity over whole range of shear rates among breeds and gender (p<0.05). The results suggested that correlation between whole blood viscosity and regular blood test such as complete blood cell count and serum chemistry in pigs and can be used as a reference data for further investigation.
Biography
Jun Koh is doing his graduate course in Department of Surgery, College of Veterinary Medicine, Chonbuk National University from 2012. His major is small animal general surgery and a field of research is related in general surgery and hemorheology .